1. improved wxKill() implementation for Win32
2. added wxKillError output parameter to wxKill 3. added wxProcess::Kill() and Exists() 4. documented all the new stuff 5. updated the sample to show it git-svn-id: https://svn.wxwidgets.org/svn/wx/wxWidgets/trunk@10592 c3d73ce0-8a6f-49c7-b76d-6d57e0e08775
This commit is contained in:
@@ -513,65 +513,204 @@ bool wxSetEnv(const wxString& var, const wxChar *value)
|
||||
// process management
|
||||
// ----------------------------------------------------------------------------
|
||||
|
||||
int wxKill(long pid, wxSignal sig)
|
||||
#ifdef __WIN32__
|
||||
|
||||
// structure used to pass parameters from wxKill() to wxEnumFindByPidProc()
|
||||
struct wxFindByPidParams
|
||||
{
|
||||
#ifndef __WIN32__
|
||||
return -1;
|
||||
#else
|
||||
// This in a work in progress. We need to eliminate the call to wxSleep,
|
||||
// deal with child processes, and also test it :-)
|
||||
HWND hHwnd;
|
||||
HANDLE hProcess;
|
||||
unsigned long code;
|
||||
bool terminateSuccess = TRUE;
|
||||
wxFindByPidParams() { hwnd = 0; pid = 0; }
|
||||
|
||||
hProcess = OpenProcess(PROCESS_TERMINATE | PROCESS_QUERY_INFORMATION,
|
||||
FALSE, (unsigned long)pid);
|
||||
if (hProcess == NULL)
|
||||
return -1;
|
||||
// the HWND used to return the result
|
||||
HWND hwnd;
|
||||
|
||||
if (sig == wxSIGKILL)
|
||||
terminateSuccess = (TerminateProcess(hProcess, 0) != 0);
|
||||
else if (sig != wxSIGNONE)
|
||||
// the PID we're looking from
|
||||
DWORD pid;
|
||||
};
|
||||
|
||||
// wxKill helper: EnumWindows() callback which is used to find the first (top
|
||||
// level) window belonging to the given process
|
||||
BOOL CALLBACK wxEnumFindByPidProc(HWND hwnd, LPARAM lParam)
|
||||
{
|
||||
DWORD pid;
|
||||
(void)::GetWindowThreadProcessId(hwnd, &pid);
|
||||
|
||||
wxFindByPidParams *params = (wxFindByPidParams *)lParam;
|
||||
if ( pid == params->pid )
|
||||
{
|
||||
hHwnd = ::FindWindow(NULL, NULL);
|
||||
while (hHwnd != 0)
|
||||
// remember the window we found
|
||||
params->hwnd = hwnd;
|
||||
|
||||
// return FALSE to stop the enumeration
|
||||
return FALSE;
|
||||
}
|
||||
|
||||
// continue enumeration
|
||||
return TRUE;
|
||||
}
|
||||
|
||||
#endif // __WIN32__
|
||||
|
||||
int wxKill(long pid, wxSignal sig, wxKillError *krc)
|
||||
{
|
||||
#ifdef __WIN32__
|
||||
// get the process handle to operate on
|
||||
HANDLE hProcess = ::OpenProcess(SYNCHRONIZE |
|
||||
PROCESS_TERMINATE |
|
||||
PROCESS_QUERY_INFORMATION,
|
||||
FALSE, // not inheritable
|
||||
(DWORD)pid);
|
||||
if ( hProcess == NULL )
|
||||
{
|
||||
if ( krc )
|
||||
{
|
||||
if (::GetParent(hHwnd) == 0)
|
||||
if ( ::GetLastError() == ERROR_ACCESS_DENIED )
|
||||
{
|
||||
unsigned long testpid = 0;
|
||||
GetWindowThreadProcessId(hHwnd, &testpid);
|
||||
if ((unsigned long)pid == testpid)
|
||||
*krc = wxKILL_ACCESS_DENIED;
|
||||
}
|
||||
else
|
||||
{
|
||||
*krc = wxKILL_NO_PROCESS;
|
||||
}
|
||||
}
|
||||
|
||||
return -1;
|
||||
}
|
||||
|
||||
bool ok = TRUE;
|
||||
switch ( sig )
|
||||
{
|
||||
case wxSIGKILL:
|
||||
// kill the process forcefully returning -1 as error code
|
||||
if ( !::TerminateProcess(hProcess, (UINT)-1) )
|
||||
{
|
||||
wxLogSysError(_("Failed to kill process %d"), pid);
|
||||
|
||||
if ( krc )
|
||||
{
|
||||
PostMessage(hHwnd, WM_QUIT, 0, 0);
|
||||
// How to make this better?
|
||||
// If we don't wait, the return value is wrong.
|
||||
wxSleep(1);
|
||||
break;
|
||||
// this is not supposed to happen if we could open the
|
||||
// process
|
||||
*krc = wxKILL_ERROR;
|
||||
}
|
||||
|
||||
ok = FALSE;
|
||||
}
|
||||
break;
|
||||
|
||||
case wxSIGNONE:
|
||||
// do nothing, we just want to test for process existence
|
||||
break;
|
||||
|
||||
default:
|
||||
// any other signal means "terminate"
|
||||
{
|
||||
wxFindByPidParams params;
|
||||
params.pid = (DWORD)pid;
|
||||
|
||||
// EnumWindows() has nice semantics: it returns 0 if it found
|
||||
// something or if an error occured and non zero if it
|
||||
// enumerated all the window
|
||||
if ( !::EnumWindows(wxEnumFindByPidProc, (LPARAM)¶ms) )
|
||||
{
|
||||
// did we find any window?
|
||||
if ( params.hwnd )
|
||||
{
|
||||
// tell the app to close
|
||||
//
|
||||
// NB: this is the harshest way, the app won't have
|
||||
// opportunity to save any files, for example, but
|
||||
// this is probably what we want here. If not we
|
||||
// can also use SendMesageTimeout(WM_CLOSE)
|
||||
if ( !::PostMessage(params.hwnd, WM_QUIT, 0, 0) )
|
||||
{
|
||||
wxLogLastError(_T("PostMessage(WM_QUIT)"));
|
||||
}
|
||||
}
|
||||
else // it was an error then
|
||||
{
|
||||
wxLogLastError(_T("EnumWindows"));
|
||||
|
||||
ok = FALSE;
|
||||
}
|
||||
}
|
||||
else // no windows for this PID
|
||||
{
|
||||
if ( krc )
|
||||
{
|
||||
*krc = wxKILL_ERROR;
|
||||
}
|
||||
|
||||
ok = FALSE;
|
||||
}
|
||||
}
|
||||
hHwnd = GetWindow(hHwnd, GW_HWNDNEXT);
|
||||
}
|
||||
|
||||
// the return code
|
||||
DWORD rc;
|
||||
|
||||
if ( ok )
|
||||
{
|
||||
// as we wait for a short time, we can use just WaitForSingleObject()
|
||||
// and not MsgWaitForMultipleObjects()
|
||||
switch ( ::WaitForSingleObject(hProcess, 500 /* msec */) )
|
||||
{
|
||||
case WAIT_OBJECT_0:
|
||||
// process terminated
|
||||
if ( !::GetExitCodeProcess(hProcess, &rc) )
|
||||
{
|
||||
wxLogLastError(_T("GetExitCodeProcess"));
|
||||
}
|
||||
break;
|
||||
|
||||
default:
|
||||
wxFAIL_MSG( _T("unexpected WaitForSingleObject() return") );
|
||||
// fall through
|
||||
|
||||
case WAIT_FAILED:
|
||||
wxLogLastError(_T("WaitForSingleObject"));
|
||||
// fall through
|
||||
|
||||
case WAIT_TIMEOUT:
|
||||
if ( krc )
|
||||
{
|
||||
*krc = wxKILL_ERROR;
|
||||
}
|
||||
|
||||
rc = STILL_ACTIVE;
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
GetExitCodeProcess(hProcess, &code);
|
||||
CloseHandle(hProcess);
|
||||
|
||||
if (sig == wxSIGNONE)
|
||||
else // !ok
|
||||
{
|
||||
if (code == STILL_ACTIVE)
|
||||
return 0;
|
||||
else
|
||||
return -1;
|
||||
// just to suppress the warnings about uninitialized variable
|
||||
rc = 0;
|
||||
}
|
||||
else
|
||||
|
||||
::CloseHandle(hProcess);
|
||||
|
||||
// the return code is the same as from Unix kill(): 0 if killed
|
||||
// successfully or -1 on error
|
||||
if ( sig == wxSIGNONE )
|
||||
{
|
||||
if (!terminateSuccess || code == STILL_ACTIVE)
|
||||
return -1;
|
||||
else
|
||||
if ( ok && rc == STILL_ACTIVE )
|
||||
{
|
||||
// there is such process => success
|
||||
return 0;
|
||||
}
|
||||
}
|
||||
#endif
|
||||
else // not SIGNONE
|
||||
{
|
||||
if ( ok && rc != STILL_ACTIVE )
|
||||
{
|
||||
// killed => success
|
||||
return 0;
|
||||
}
|
||||
}
|
||||
#else // Win15
|
||||
wxFAIL_MSG( _T("not implemented") );
|
||||
#endif // Win32/Win16
|
||||
|
||||
// error
|
||||
return -1;
|
||||
}
|
||||
|
||||